產品

UTR2830E LCR

品牌 UNI-T | 型號 UTR2830E | 🇨🇳 China
UTR2830E LCR 4.3 TFT-LCDdisplay, supports display, Frequency20Hz~300kHz,,,, 0.05% Accuracy, supports10,., and,.
缺貨中
瀏覽次數: 16

功能介紹

type

type display Frequency Accuracy Resolution DCR standardAccessories
UTR2833E4.3'' TFT LCD300kHz0.00056 12.5ms/ YesUSB DeviceRS-232 Handler LAN
UTR2832E4.3'' TFT LCD200kHz0.00056 12.5ms/ YesUSB DeviceRS-232 Handler LAN
UTR2830E4.3'' TFT LCD100kHz0.00056 12.5ms/ YesUSB DeviceRS-232 Handler LAN

4.3'' LCD LCDdisplay

4.3 TFTLCD display,

,

supports /

4.3'' LCD LCDdisplay

supports / measurement

supports and measurement

supportsDCRmeasurement

supports / measurement

3 measurement

: 12.5ms/

: 83ms/

: 167ms/

3 measurement

4

/ / /

: Yes

: Trig,

: Handler to,

4

/

: 10, Handler

: and, display

 /

201

20~200kHz Frequency

Frequency: 20~200kHz

Accuracy: 0.05%

Display Counts: 6

20~200kHz Frequency

-standardAccessoriesUSB RS-232

-supportsSCPI

, measurement

Accessories

type
AccessoriesUTR-001
UTR-L1ME
Power Supply +
RS-232
UTR-S100KELCR

Accessories

type
AccessoriesUTR-S120MSLCR SMD
AccessoriesUTR-L1MSELCR

量測範圍

  • display4.3'' TFT LCD
  • Frequency300kHz
  • Accuracy0.05%
  • Resolution6
  • Specification12.5ms/
  • DCR√
  • standardAccessoriesRS-232,USB DeviceUSB Host,Handler,LAN

量測功能

  • 4/ / /
  • 4.3'' LCD LCDdisplay4.3 TFTLCD display,
  • supports / measurementsupports and measurement
  • 3 measurement: 12.5ms/
  • /: 10, Handler
  • Specification201
  • 20~200kHz FrequencyFrequency: 20~200kHz
  • Specification

產品規範

  • typeUTR2833E、UTR2832E、UTR2830E

產品問與答

Q Qand D Yes?
A inductance QYes,,,
resistance,.
capacitance, D, D=1/Q. D, capacitance,.
Q LCR 1KΩ 1.3KΩ, 33nF 10Khz 400pF, 1μF 120Hz 830nF, ?
A 1.YesNoYes and ?
2. Yesstandard ?
3. measuring rangeYesNoYesAUTO
Q LCR DCR Yes ?
A DCRYes resistancemeasurement:
measurement and
Q Handler ?
A 1. Handler, Handler.
2. LCR UTR-S100KE.
3. LCR.
4. LCR measurement,.
5., display display.
Q LCR display SERandPAR, and ?
A LCR SERandPAR measurement(capacitanceC, inductanceL, resistanceR),. measurementAccuracy.
(≤1kΩ)→ SER( capacitance, inductance, resistanceresistance ).
(≥10kΩ)→ PAR( capacitance, resistanceresistance, ).
Q LCR capacitance ?
A 1.
2. Frequency ( capacitance to120Hzor1Khz)
3.: capacitance suitable for Cp
Q Calibration?
A Calibrationand Calibration, Yes measurement(>100kHz), (<1Ω)or Yes AccuracyYes, Calibration. Yes Yes or Yes, measurement Calibration.
Q to ?
A Yes Calibration, Calibration to, standardAccessories. Calibration,, to Calibration.
Q LCR and multimeters ?
A LCR and multimeters measurement Yes, multimeters “ ”, measurement, type, measurement“Yes Yes”. LCR “ ”, measurement,, measurement“ ”. multimeters measurement Frequencyand measurement, No. LCR measurement Frequency( 100Hz, 1kHz, 10kHz),, Voltage, measurement: Q, D, resistanceESR, Z and θ.